Output voltage monitor
Range: 0 ~ 1000 V
Real time display of output voltage of the VFD
01.09
Output power monitor
Range: 0.0 ~ 1000 kW
Real time display of power consumption of the VFD
It displays in 0.1 unit if the motor current is under 1000kW
It displays in 1 unit if the motor current is above 1000kW
below determined by equation:
Power: √3 x V x I
'01.09'
ex)
'01.05' (Motor current monitor)
= 1.37 X
82
'01.08' (Output voltage monitor)
X