Adtech iMASTER – A1 Series User Manual page 156

Table of Contents

Advertisement

A1-User's Manual
40.22
ref source 2 at PID disable
See the parameter '40.21' (ref source 1 at PID disable)
40.23
ref 1/ref 2 combination at PID disable
0: '40.21' ----- Initial value
1: '40.21' + '40.22'
2: '40.21' - '40.22'
3: '40.21' x '40.22'
4: MIN ('40.21', '40.22')
5: MAX ('40.21', '40.22')
Selects a mathematical function between the reference sources selected by parameters
'40.21' (ref source 1 at PID disable) and '40.22' (ref source 2 at PID disable)
Set 0:
'40.21' (ref source 1 at PID disable)
Set 1:
'40.21' (ref source 1 at PID disable) + '40.22' (ref source 2 at PID disable)
Set 2:
'40.21' (ref source 1 at PID disable) - '40.22' (ref source 2 at PID disable)
Set 3:
'40.21' (ref source 1 at PID disable) x '40.22' (ref source 2 at PID disable)
Set 3:
MIN '40.21' (ref source 1 at PID disable), '40.22' (ref source 2 at PID disable)
Set 5:
MAX '40.21' (ref source 1 at PID disable), '40.22' (ref source 2 at PID disable)
'40.21'
'40.21'+ '40.22'
'40.21'- '40.22'
'40.21'x '40.22'
MIN ('40.21', '40.22')
MAX ('40.21', '40.22')
152