A1-User's Manual
43.04
Droop gain
Range: 0.00 ~ 50.00 in 0.01
Initial value: 5.00
Sets the reduced rate of output frequency when at the 100% output torque gain while
operating in the droop control
43.05
Droop start torque
Range: 0.0 ~ 100.0 % in 0.1 %
Initial value: 0.0 %
Set the amount of output torque at start in droop control
43.06
Droop ramp time
Range: 1.0 ~ 100.0 Sec in 0.1 Sec
Initial value: 20.0 Sec
Set the response time of output change when operating droop control
If this time is short, it occur the vibration
If this time is long, it occur the delayed response of droop control