Adtech iMASTER – A1 Series User Manual page 177

Table of Contents

Advertisement

A1-User's Manual
98.10
Manual torque boost frequency reference
Range: 0.0 ~ 100.0 % in 0.1 %
Initial value: 100.0 %
Program the frequency breakpoint
It not works in auto torque mode or sensorless mode
100 %
98.09
98.11
Motoring Slip Compensation
Range: 0 ~ 200 % in 1%
Initial value: 0 %
When a load is applied, Slip is compensated to keep the speed constant.
(Apply V/f Control only)
98.12
Regeneration Slip Compensation
Range: 0 ~ 200 % in 1%
Initial value: 0 %
When a load is applied, Slip is compensated to keep the speed constant.
(Apply V/f Control only)
'21.01', '98.01', '98.09'
Related Parameters:
Ex1: 98.09 (Manual torque boost voltage reference)= 5%,
V
98.10 (Manual torque boost frequency reference) = 10%
10%
=5%
5%
98.10
=10%
99.02 (Motor rated voltage)
F(Hz)
173