Adtech iMASTER – A1 Series User Manual page 134

Table of Contents

Advertisement

A1-User's Manual
25.06
RefIq
LP
Iq
F
Feedback
Current
25.05
OutF
req Generation
Block
25.01
OVS selection
0: Disable ----- Initial value
1: Enable
Select to enable the Voltage Suppression Control function.
25.02
Maximum OVS output frequency
Range: 0.0 Hz ~ 300.0 Hz in 0.01 Hz
Initial value: 20.00 Hz
Real time editable a maximum frequency limit for OVS function
25.03
OVS P gain
Range: 0 ~ 10000 in 1
Initial value: 1000
Real time editable P gain for OVS PID loop
Example
25.04
OVS I gain
PID P Gain
25.03
P
PID I Gain
PI Limit
25.04
+
+
I
+
PID D Gain
25.05
D
Max Freq
30.01
OutFreq
0
Related Parameters:
PIOut = err * Kp
Hz = err(%) * Kp * scalefactor(50 * 1e-6)
err 10%, Kp = 1000
PIOut = 0.5Hz
Recommended Value in test bench
1000 or less than 5000
PI Limit = 25.02 (Max Out Freq )-
LIMIT
FreqAdd
0
Max Out Freq
25.02
LIMIT
+
+
0
Meaning of 25.02 is changed from Max Add Freq to Max Out Freq
130
OutFreq ; Internally calculated
OutFreqFinal