MP9800 Series
Access 600 Integrated Wiegand
with and without MELR Option (Electric Latch Retraction)
Multi-Point Lock
Installation Instructions
11
Installation continued
H. Attach trim ground wire.
1. Connect pin 5 green/yellow ground wire ring
terminal (from inside trim) to top left screw.
(Figure 15)
I. Connect Electrolynx
(for Access 600 x M802)
NOTE: If installing an Access 600 M812
proceed to step K.
1. Connect P3 (2-pin connector) from lockbody
or MELR assembly to J3 on interior PCB
assembly.
2. Connect P4 (6-pin connector) from lockbody
assembly to J4 on interior PCB assembly.
3. Connect P5 (7-pin connector) from Reader
board to J5 on interior PCB assembly.
4. Connect ElectroLynx
from door harness to ElectroLynx
on interior PCB assembly. (Figure 16)
NOTES:
• Connectors attach properly in only one
orientation.
• Do not offset connector.
• Be sure connection is secure by gently
tugging on wire.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
harness.
®
harness (4 and 8-pin)
®
8-pin
ElectroLynx
4-pin
ElectroLynx
harness
®
J2
To ElectroLynx
Harness
From Lock
Body P4 to J4
14
Figure 15
From Reader
Board P5 to J5
J1
From Lock
Body or MELR
Assembly
P3 to J3
Figure 16