Installation continued
D. Install outside escutcheon.
1. Feed reader cable connector located
on back of outside escutcheon from
outside of door through ribbon cable
hole on door. (Figure 6)
E. Install inside mounting plate on multi
point lock without MELR.
1. Securely tighten outside escutcheon
with two (2) #8-32 x 2" Phillips flat head
screws through mounting plate.
(Figure 6)
F. Install inside mounting plate on multi
point lock with MELR.
1. Prepare MELR mounting holes if
required.
IMPORTANT: If manufacturer has
not pre-drilled door, prepare door
per instructions below, using plastic
template included with device. Screw
hole orientation is not affected by
handing. If door is pre-drilled by
manufacturer, continue to step G.
2. Mark vertical centerline of slot and wire
hole on door. (Figure 7)
3. Mount template onto plate. For
wood doors, ensure template notch
is touching rod to provide lateral
positioning. (Figure 8)
4. Check that template is square to door.
(Figure 9)
5. Using template bushings as a
guide, drill four (4) 1/16" holes.
(Figure 10)
6. Remove template.
7. For metal door, increase
1/16" pilot holes to #29
(.136) and tap for #8-32.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Mark
Vertical
Centerline
Wire
Hole
Figure 7
Template
in Position
Detail of Notch in
Template Aligned to
Vertical Centerline
12
Two #8-32 x 2" Phillips
Flat Head Screws
Figure 6
(Wood Door
Location Detail of
Template Notch
Touching Rod and
Resting on Plate
Figure 8
Centerline
Template
Figure 10
Wire Hole
Figure 9
Shown)
Template
Holes