Assa Abloy Corbin Russwin MP9800 Series Installation Instructions Manual page 16

Access 600 integrated wiegand with and without melr option (electric latch retraction) multi-point lock
Hide thumbs Also See for Corbin Russwin MP9800 Series:
Table of Contents

Advertisement

MP9800 Series
Access 600 Integrated Wiegand
with and without MELR Option (Electric Latch Retraction)
Multi-Point Lock
Installation Instructions
11
Installation continued
L. Connect ElectroLynx harness.
(For Access 600 x M812)
1. Connect P5 (7 Pin Connector) from reader
board to J5 on interior escutcheon PCB
assembly. (Figure 20)
2. Connect ElectroLynx harness (4 and 8-pin)
from door to interior PCB assembly.
(Figure 20)
NOTES:
• Neatly fold wires into remaining space to
prevent pinching wires when mounting
escutcheon.
• Do not tuck extra mortise lockbody wires
back inside lockbody cylinder hole.
• Connectors attach properly in only one
orientation.
• Do not offset connector.
• Be sure connection is secure by gently
tugging on wire.
8-pin
ElectroLynx
4-pin
ElectroLynx
M. Install controller.
(For Access 600 x M812)
1. Once wires are arranged, position
controller at a rotated angle against
door, under earth ground wire.
2. Press piece against door while turning
clockwise. (Figure 21)
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
1-Violet Lock Neg
3-Pink
Actuator (+)
-
Solenoid (-)
2-Gray Lock Pos
4-Tan
Actuator (+)
-
Solenoid (-)
16
J2
J1
P5
Figure 20
J1
1- Black
3-White
5-Orange
PWR NEG
DATA 1
RX (NO)
2-Red
4-Green
6-Blue
PWR POS
DATA 0
RX (COM)
Rotate Clockwise
Figure 21
7-Brown
EGND
8-Yellow
LED
FM437 11/18

Advertisement

Table of Contents
loading

Table of Contents