Access 600 integrated wiegand with and without melr option (electric latch retraction) multi-point lock
Hide thumbs Also See for Corbin Russwin MP9800 Series:
Table of Contents

Advertisement

MP9800 Series
Access 600 Integrated Wiegand
with and without MELR Option (Electric Latch Retraction)
Multi-Point Lock
Installation Instructions
6

Wiring Diagram - Typical Access 600 Application (12/24VDC Lock)

Mode 1:
LED wire not used = RED LED
"ON" when powered
NOTE: Standard Application Shown.
For Alternative Applications Contact
1-800-810-WIRE (9473)
*Reader Electronics Require 12 or
24VDC UL294 Listed, Power Limited
Power Supply (or UL603)
Door
Position Switch
12 Conductor
ElectroLynx Harness
From McKinney
Access 600 Series
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Access 600 M802
12VDC / 24VDC System:
• Reader Draw= 150mA
• Actuator Draw= 400mA
(inrush / 15mA continuous)
• Total System Draw = 550mA
12VDC System (MELR):
• Reader Draw = 150mA
• 12VDC MELR Module Draw =
850mA
• Total System Draw = 1 Amp
24VDC System (MELR):
• Reader Draw = 150mA
(Reader is always 12VDC)
• 12VDC MELR Module Draw =
700mA
• Total System Draw = 850mA
MELR not evaluated for UL 294 compliance, CAN/ULC-S319-05 and BHMA A156.25
Lockbody
Power Supply
(By Others)
ULC-S319 compliance:
EAC power supply utilizing battery backup
(30 minutes operation) is required.
READER NEG - Black, 1
READER POS - Red, 2
QC12 Electric
DATA 1 - White, 3
Hinge From
DATA 0 - Green, 4
McKinney
RX NO NC
(
/
) - Orange, 5
RX COM
(
) - Blue, 6
*
EGND
- Brown, 7
LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
6
Access 600 M812
• Reader Draw= 125mA
• Actuator Draw= 400mA
(inrush / 15mA continuous)
• Total System Draw = 525mA
• Reader Draw = 125mA
• 12VDC MELR Module Draw=
850mA
• Total System Draw = 975mA
• Reader Draw = 125mA
• 12VDC MELR Module Draw =
700mA
• Total System Draw = 825mA
*Access 600 M812
H
N
G
Requires 12 or 24VDC
120 VAC
UL294 Listed, Power Limited
Input
12/24VDC
Power Supply (or UL603)
-
+
(-)
12VDC
(+)
DATA 1
D ATA 0
RX
Use (
NC
) for
RX
Fail Safe
Operation
Not Used
DPS
(
NO
) Fail
Secure
DPS
Operation
IMPORTANT: Pin 7 must be tied to earth ground in the
access control panel. Failure to follow proper ESD safe
grounding procedures could lead to equipment failure.
Electronic Access
Control Panel
(By Others)
Lock Relay
FM437 11/18