G. Install MELR assembly.
1. Install upper left mounting screw.
#8 - 32 x 5/8" Fillister head for metal door or
#8 x 5/8" self tapping wood screw for wood
doors. (Figure 11)
NOTE: Leave screw loose enough to slide
MELR assembly on.
2. Snake wire through MELR assembly.
3. Slide mounting bracket of MELR assembly
underneath installed screw and secure in
place.
IMPORTANT: Ensure MELR retraction
lever is resting on plate. (Figure 12)
4. Completely tighten upper left mounting
screw.
IMPORTANT: Be careful not to pinch or
disconnect wires.
5. Install remaining three (3) #8-32 x 5/8"
Fillister mounting screws on metal doors or
remaining three (3) #8 x 5/8" self tapping
wood screws on wood doors. (Figure 13)
6. Install two (2) 1/4" self-tapping screws on
either diagonal; one above molex connector
and one below. (Figure 14)
7. Connect 8-pin molex
connectors.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Upper Left
Mounting
Screw
Figure 12
#8-32 x 5/8"
(2) 1/4"
Self-Tapping
Screws
Figure 14