4.1 Opening the Housing ..................9 4.2 Wiring Runs ..................... 10 4.3 Selection of A or B-bus ..................11 4.4 ELISE2 controlling the Communication on the A/B-bus ........11 4.5 Mounting ......................13 4.6 Mounting Together with Other Units ..............13 4.7 System 900 Addressing ..................
TD 92232GB ELISE2 Introduction The ELISE2 module can be used as a platform for a wide range of applications. The module can be used as an interface between systems, for example a TCP/IP network and the System 900 bus. The licence is application dependent and therefore described in the application documentation.
Page 5
S1, S2 Jumper points for selection of A or B-bus For internal use only S4, S5 Jumper points used when ELISE2 controls the communication on the A/B-bus. Reset button for CPU Switches Module address selector switch for A or B-bus. If the setting of SW2 is changed, the ELISE2 module detects this automatically and will reconnect to the System 900 with the new address (it takes approximately 30 s).
Network Setup Mode To be able to contact the ELISE2, a valid and unique IP address is necessary. In this mode, the IP address is set to 192.5.36.229, which is reserved for installation of ELISE2. Network Setup Mode should only be used when ELISE2 has not got any IP address or when the IP address has to be changed, i.e.
Software on page 25. Unlicensed Mode It is possible to run the ELISE2, with limited functionality, without a licence. How the mode functions is application dependent. For more exact information about the functionality during unlicensed mode, see the application documentation.
Installation Guide TD 92232GB ELISE2 Starting the unit in Normal Mode Set all sections on SW3 to OFF. Open the page System Setup > General on the administration web page and check that the correct licence is entered. Press "Reboot".
Each segment = 100 ms Fail safe mode is indicated, even if SW3 pin 2 is not set to ON, if the application on ELISE2 is not completely installed or when the application part of the Compact Flash is erased.
In addition, there are two other users in some ELISE2 products. One is called user and the default password is "password". This user is product dependent and what it is used for is described in corresponding product documentation.
4.3 Selection of A or B-bus on page 11. At delivery, the ELISE2 is configured to be connected to a Central Unit on the A/B- bus. If the ELISE2 should control the communication on the A/B-bus, follow instructions in 4.4 ELISE2 controlling the Communication on the A/B-bus...
Use pliers to break off a suitable section. Run the wiring out through the partition. Wiring can be run three ways from the ELISE2 module: • Remove the rectangular covers and run the cabling out through the side (1). • Break off sections at short side of case and run the cabling downwards (2).
This can be useful when System 900 is not used for messaging but only to communicate with, for example, an Alarm Module or Output Module. The same information that can be received when the ELISE2 is connected to an A-bus with Central Unit, can also be received when it is controlling the communication. Examples of information is input activity and pagings from the Alarm Modules (see respective software application documentation for more information about the possibilities).
Page 14
When the ELISE2 controls the communication on the A-bus, a maximum of 15 modules can be connected to the A-bus. The ELISE2 should have the address 00 and other modules that are connected to the A-bus must have addresses in the range 01-0F.
Installation Guide TD 92232GB ELISE2 Mounting Dimensions for installation of the ELISE2 module. Dimensions (H x W x D) 275 x 130 x 60 mm 56,5 188,5 Note: To facilitate service after the unit is installed, we recommend a free space of about 150 mm above and 50 mm below the unit.
LED7 RS232:3 RS232:2 RS232:1 Figure 8. The ELISE2 module addressing switch. Connection of System Bus The ELISE2 module can be installed together with other System 900 units, either via modular system bus cabling or via twisted-pair lines. 2005-06-15 / Ver.G...
Page 17
J12 J13 Other unit The illustration above shows an ELISE2 module placed to the left of another System 900 unit. Connect the bus cable as shown, from connector J12/J13 on the ELISE2 module to the bus connector on the other unit.
Installation Guide TD 92232GB ELISE2 Connection of Supply Voltage A separate power supply is connected to screw connector J5, pin1 and 2. A ferrite bead is thread on the wire to prevent EMC disturbances. The current through J5 must not exceed 3A.
TD 92232GB ELISE2 4.10 Additional Connections Error Relay Output A relay output on connector J14 is used to indicate ELISE2 module malfunction and can also be used to indicate other errors. See application documentation for more information about functionality. ELISE Error relay output Figure 12.
Page 20
Galvanic isolation of the inputs and outputs is provided by using a separate power supply. When galvanic isolation is not needed, supply voltage can be taken from the ELISE2 circuit board by connecting J16-1 to J5-3 and J16-6 to J5-4.
Installation Guide TD 92232GB ELISE2 1 External +12 V Pull-up 2 IN1 resistor 3 IN2 External 4 OUT1 equipment 5 OUT2 6 External GND Figure 16. Connection of inputs and outputs. The inputs IN1 and IN2 are active when they are connected to 12 V. When the output...
If the function indicator is red, check that supply voltage is 12.5 Vdc ±10%. To be able to access ELISE2 from a PC, the PC has to belong to the same network as ELISE2 or ELISE2’s IP address has to be found in the PC’s route table. To facilitate this, the program "Route to ELISE"...
Page 23
(xxx.xxx.xxx.xxx is the IP address that was given to ELISE2 during network setup) and see that it has started up correctly. If an entry is added in the DNS, it will be easier to connect to ELISE2. 2005-06-15 / Ver.G...
ELISE2 4.13 Connection of Ethernet If ELISE2 is connected directly to a PC, a crossover cable has to be used. If ELISE2 is connected to a HUB, an ordinary (straight through pinouts) cable has to be used. The cable supplied is an ordinary cable.
ELISE2 4.15 Clock Synchronisation and Time Settings The clock in different ELISE2 modules can be set from the web browser, A-bus (i.e. Central Unit in System 900) or a time server. To be able to synchronise the clocks in different ELISE2 modules a time server has to be used.
• No module addressing 127.0.0.1/S900 The data is sent to the System 900 interface in the ELISE2 module, which sends the data on the A-bus without the module address defined. The Central Unit in the system has to be configured to distribute the data to a module. It is also possible to address the System 900 interface on another module by entering its IP address instead of 127.0.0.1 (localhost).
ELISE2 4.17 Unite Name Server (UNS) The UNS is used to resolve addresses into complete Unite destinations. The ELISE2 can be configured to send all requests to the local UNS (stand-alone mode) or to forward all requests to a centralised UNS (forwarding mode). In forwarding mode, the local UNS will only be used if the centralised UNS cannot resolve the address.
Installing an Image on an empty Compact Flash An image can also be installed on an empty Compact Flash. Set section one and four in SW3 to ON, to set the ELISE2 in "Network setup mode" and "Image installation mode".
Installation Guide TD 92232GB ELISE2 Circuit Board Replacement Figure 20. Replacing the ELISE2 circuit board. Perform a power down of the unit. Remove the cover, see 4.1 Opening the Housing on page 9. Lift off the screw connectors from the circuit board. (1) Press the four holding clips to release the circuit board (2).
Connection for the teleCARE M LON (only use terminals 1 and 2) Connector for In System Programming (ISP) of the flash micro controller Male connector to be put on J9 on ELISE2 circuit board. Pin 12 cut off Male connector to be put on J10 on ELISE2 circuit board...
Page 31
Attach the LPB on the ELISE2 circuit board. Carefully line up the male connector pins of the LPB with the female connector of the ELISE2, then press the LPB down firmly. (To avoid misalignment, the pin 12 on the J3 connector of the LPB is cut off and the corresponding hole on the J9 connector of ELISE2 plugged).
Page 32
Max. 2 x 0.8 mm ø wire at each connector. Strip 10 cm teleCARE M LON Figure 22. Cabling of screw connector J1 Replace all removed connectors Close the cover and restart ELISE2, see 3.2 Power Down and Restart of ELISE2 page 4. 2005-06-15 / Ver.G...