8. General Specifications
Refer to GS 01W06F01-01EN for the latest information.
8.1
Standard
Specifications
n Measurement Range
Pressure:
Measurement
Range
Gauge
−0.1 to 5 MPa*
Pressure*
1
(−14.5 to 720 psi)
*1: Pressure measurement span cannot be
changed
*2: Refer to Figure 1 if the pressure is below
atmospheric pressure.
100 (14.5)
Applicable range
10 (1.4)
2.7 (0.38)
1 (0.14)
0
−40
(32)
(−40)
Process temperature °C (°F)
Fig.8-1 Working Pressure and Process Temperature
Temperature:
–40 to 85°C (–40 to 185°F)
Maximum
Pressure
2
7.5 MPa
(1080 psi)
Atmospheric
pressure
40
80
120
(104)
(176)
(248)
50
97.2
(122)
(207)
F14.ai
<General Specifications>
n PERFORMANCE
SPECIFICATIONS
Measurement Accuracy:
Pressure*: ± 0.25% of Full scale
Temperature: ± 5°C typ.
*: Measurement Accuracy will be changed
when electromagnetic noise applied.
Ambient Temperature Effects
(zero shift):
± 0.02 (% of Full scale/°C)
Attitude Error:
about 300 Pa/90°
Rotation in diaphragm plane has
no effect.
Atmospheric Pressure
Fluctuation Error:
0.02 (% of Full scale/1 kPa)
Temperature Measurement Unit:
internal sensor of the Pressure
Measurement Module
Update Time:
1 minute to 3 days
Battery Characteristics:
Battery life is 10 years under the
following conditions*.
• Ambient temperature: 23±2°C
• Update Time: 1 hour
*: Environmental condition such as vibration
may affect the battery life.
8-1