Restrictions On Use Of Radio Transceivers; Explosion Protected Instrument - YOKOGAWA Sushi Sensor XS530 User Manual

Pressure measurement module
Table of Contents

Advertisement

2.6

Restrictions on Use of Radio Transceivers

IMPORTANT
Although this product has been designed to prevent high frequency noise,
the effect of high frequency noise may occur if the transceiver is used
near the product and its wiring. Therefore, when using the transceiver,
investigate the effect of the transceiver beforehand, and use the
transceiver at a distance where the problem does not occur.
2.7

Explosion Protected Instrument

2.7.1
ATEX Intrinsic Safety
Technical data:
• Certificate number: DEKRA 20ATEX0024 X
• Applicable standards: EN IEC 60079-0:2018, EN 60079-11:2012
• Ex marking:
• Ambient temperature: −40 to 60°C (–40 to 140°F)
• Process temperature: −40 to 100°C (–40 to 212°F)
• Electrical parameters:
Connector
Ui = 6.88 V, Ii = 1.54 A, Pi = 0.3 W, Ci = 3.9 μF, Li = 0 μH
• Enclosure: IP66/IP67 in accordance with only EN 60529 when combined
with XS110A.
Certification information:
WARNING
A modification of the equipment would no longer comply with the
construction described in the certificate documentation.
II 2 G Ex ib IIC T4 Gb
<Notes on Handling>
IM 01W06F01-01EN
2-4

Advertisement

Table of Contents