DIAGNOSTIC TROUBLE CODES (DTCS) – MATRYX
SPN = SUSPECT PARAMETER NUMBER / FMI = FAILURE MODE INDICATOR
TROUBLE CODE
Exhaust Valve
Learning Default
Position
Water Temperature
Unrealistic
Transition
DIAGNOSTIC TROUBLE CODES (DTCS) – LEFT
HAND CONTROLS
MATRYX LEFT HAND CONTROLS – DIAGNOSTIC TROUBLE CODES (DTCS)
SPN = SUSPECT PARAMETER NUMBER / FMI = FAILURE MODE INDICATOR
SPN
FMI
0
5
516360
6
31
DIAGNOSTIC TROUBLE CODES (DTC)
SPN
FMI
520337
7
110
10
P-
DESCRIPTION
CODE
C1106
Left Grip Heater
Driver Over Temp
C1107
Left Grip Heater
Driver Under
Current
C1108
Left Grip Heater
Driver Over
Current
C1109
Left Grip Heater
Driver Internal
Short
P-
CODE
P3036
This trouble code sets if the Exhaust Valve
Learn values are different from the
Exhaust Valve Check Values. Can be
caused by an obstruction in the Exhaust
Valves, Broken Cable, or broken Exhaust
Valve.
P0119
This trouble code sets if the water
temperature changes by 20C in 1sec 3
times. Can be caused by Faulty Wiring,
Faulty Water Temperature Sensor, or
Faulty ECU.
FAULT SETTING
The temperature at
left grip heater driver
is greater than 60
DegC for 5 seconds
The current at left
grip heater driver is
is less than 1A for 5
seconds
The current at left
grip heater driver is
is greater than 7A for
5 seconds
An internal short has
been detected at the
left grip heater driver.
This would result in a
100% duty cycle
output when not
expected.
CONDITION
FAULT
HEALING
The temperature
at left grip heater
driver is less
than 60 DegC for
5 seconds
The current at
left grip heater
driver is is
greater than
1.5A for 5
seconds
The current at
left grip heater
driver is is less
than 6A for 5
seconds
An internal short
is not detected at
the left grip
heater driver.
213