DIAGNOSTIC TROUBLE CODES (DTC)
MATRYX LEFT HAND CONTROLS – DIAGNOSTIC TROUBLE CODES (DTCS)
SPN = SUSPECT PARAMETER NUMBER / FMI = FAILURE MODE INDICATOR
SPN
FMI
0
5
516361
6
31
0
5
516362
6
31
214
P-
DESCRIPTION
CODE
C110A
Right Grip Heater
Driver Over Temp
C110B
Right Grip Heater
Driver Under
Current
C110C
Right Grip Heater
Driver Over
Current
C110D
Right Grip Heater
Driver Internal
Short
C110E
Thumb Heater
Driver Over Temp
C110F
Thumb Heater
Driver Under
Current
C1110
Thumb Heater
Driver Over
Current
C1111
Thumb Heater
Driver Internal
Short
FAULT SETTING
The temperature at
right grip heater
driver is greater than
60 DegC for 5
seconds
The current at right
grip heater driver is
is less than 1A for 5
seconds
The current at right
grip heater driver is
is greater than 7A for
5 seconds
An internal short has
been detected at the
right grip heater
driver. This would
result in a 100% duty
cycle output when
not expected.
The temperature at
thumb heater driver
is greater than 60
DegC for 5 seconds
The current at thumb
heater driver is is
less than 0.2A for 5
seconds
The current at thumb
heater driver is is
greater than 1.4A for
5 seconds
An internal short has
been detected at the
thumb heater driver.
This would result in a
100% duty cycle
output when not
expected.
FAULT
HEALING
The temperature
at right grip
heater driver is
less than 60
DegC for 5
seconds
The current at
right grip heater
driver is is
greater than
1.5A for 5
seconds
The current at
right grip heater
driver is is less
than 6A for 5
seconds
An internal short
is not detected at
the right grip
heater driver.
The temperature
at thumb heater
driver is less
than 60 DegC for
5 seconds
The current at
thumb heater
driver is is
greater than
0.25A for 5
seconds
The current at
thumb heater
driver is is less
than 1.2A for 5
seconds
An internal short
is not detected at
the thumb heater
driver.