Installation

7   Installation
7.1   Installation Instructions
CAUTION
Improper installation or maintenance
Personal injury or damage to property
4 During installation and maintenance, make sure that the ejector is disconnected and
depressurized and that it cannot be switched on again without authorization.
For safe installation, the following instructions must be observed:
1. Use only the connections, mounting holes and attachment materials that have been provided.
2. Carry out mounting and removal only when the device is in an idle, depressurized state.
3. Pneumatic and electrical line connections must be securely connected and attached to the ejector.
7.2   Mounting
The ejector may be installed in any position.
There are two 4.3 mm mounting holes for mounting the ejector.
When mounting with fastening screws, use M4 washers (2 Nm max. tightening torque).
For the start of operations, the ejector must be connected to the controller via the connection plug with a
connection cable. The compressed air required to generate the vacuum is connected via the compressed
air connection. The compressed air supply must be supplied by the higher-level machine.
The vacuum circuit is connected to the vacuum connection.
The installation process is described and explained in detail below.
22 / 40
EN-US · 30.30.01.02636 · 00 · 01/21