5.4   Viewing and Setting Parameters
The following parameters can be set for the ejector:
The vacuum limit value H1 for the control
The vacuum limit value H2 for the signal output
The blow off period for the time-controlled blow off
The hystereses for the vacuum limit values are pre-defined.
The table below shows the various options
For H1, the hysteresis h1 is always 20% of the H1 value; the hysteresis h2 is always 10 mbar.
LED bar dis-
play
0%
10%
20%
30%
40%
55%
65%
75%
Max.
Control function deactivated
1)
If a value > (H1-h1) is selected for H2, the hysteresis h1 is dynamically adjusted so that (H1-h1) is 25 mbar
above H2.
The value set for H1 must always be greater than the value set for H2. Only settings that meet this specifi-
cation can be made.
Setting Parameters
The LEDs assigned to the parameters flash to indicate which value is currently being displayed or changed.
Operating structure overview
EN-US · 30.30.01.02636 · 00 · 01/21
H1
200 mbar
40 mbar
300 mbar
60 mbar
400 mbar
80 mbar
550 mbar
110 mbar
650 mbar
130/75 mbar
750 mbar
150/75 mbar
h1
H2
100 mbar
200 mbar
300 mbar
400 mbar
550 mbar
1)
650 mbar
1)
750 mbar
General Description of Functions
h2
Blow off time
External
10 mbar
20 ms
10 mbar
50 ms
10 mbar
100 ms
10 mbar
250 ms
10 mbar
500 ms
10 mbar
750 ms
10 mbar
1000 ms
1500 ms
17 / 40