5.4 Viewing and Setting Parameters
The following parameters can be set for the ejector:
•
The vacuum limit value H1 for the control
•
The vacuum limit value H2 for the signal output
•
The blow off period for the time-controlled blow off
The hystereses for the vacuum limit values are pre-defined.
The table below shows the various options
For H1, the hysteresis h1 is always 20% of the H1 value; the hysteresis h2 is always 10 mbar.
LED bar dis-
play
0%
10%
20%
30%
40%
55%
65%
75%
Max.
Control function deactivated
1)
If a value > (H1-h1) is selected for H2, the hysteresis h1 is dynamically adjusted so that (H1-h1) is 25 mbar
above H2.
The value set for H1 must always be greater than the value set for H2. Only settings that meet this specifi-
cation can be made.
Setting Parameters
The LEDs assigned to the parameters flash to indicate which value is currently being displayed or changed.
Operating structure overview
EN-US · 30.30.01.02636 · 00 · 01/21
H1
—
—
200 mbar
40 mbar
300 mbar
60 mbar
400 mbar
80 mbar
550 mbar
110 mbar
650 mbar
130/75 mbar
750 mbar
150/75 mbar
h1
H2
—
—
—
100 mbar
200 mbar
300 mbar
400 mbar
550 mbar
1)
650 mbar
1)
750 mbar
—
General Description of Functions
h2
Blow off time
—
External
10 mbar
20 ms
10 mbar
50 ms
10 mbar
100 ms
10 mbar
250 ms
10 mbar
500 ms
10 mbar
750 ms
10 mbar
1000 ms
—
1500 ms
17 / 40