4.3   Factory Settings
Parameter
Limit value H1
Hysteresis value h1
Limit value H2
Hysteresis value h2
Control
Continuous suction
Blow off function
Vacuum unit
Signal output
4.4   Performance Data
Type
Nozzle size [mm]
1
Max. vacuum
[%]
1
Suction rate
[l/min]
Max. blow off capacity
min]
1
Air consumption
(suction)
(l/min]
1
Sound level
, unobstructed
suction [dBA]
1
Sound level
, suction [dBA]
Weight [kg]
1)
at 4.5 bar
4.5   Dimensions
EN-US · 30.30.01.02636 · 00 · 01/21
SCPS-L-
SCPS-L-
2-07 HV
2-09 HV
0.7
85
37
1
[l/
22
74
62
Value of the factory setting
750 mbar
150 mbar
550 mbar
10 mbar
Activated
Deactivated
Externally controlled blow off
Vacuum unit in mbar
"Normally open" contact = no
SCPS-L-
2-13 HF
0.9
1.3
61
70
145
130
45
71
77
76
63
0.5
SCPS-L-
SCPS-L-
2-16 HV
3-16 HV
1.6
90
129
227
98
102
77
80
72
Technical Data
SCPS-L-
3-20 HV
2.0
323
172
81
77
13 / 40