4   Technical Data
4.1   General Parameters
Parameter
Working temperature
Storage temperature
Humidity
Precision of vacuum sen-
sor
Degree of protection
Operating pressure (flow
pressure)
Operating medium
4.2   Electrical Parameters
Parameter
Supply voltage
Power consumption from U
2)
with NO variant
Power consumption from U
2)
with NC variant
Voltage of signal output (PNP)
Voltage of signal output
(NPN)
Power consumption of signal
output (PNP)
Power consumption of signal
output (NPN)
Voltage of signal input (PNP)
Voltage of signal input (NPN)
Current of signal input (PNP)
Current of signal input (NPN)
Reaction time of signal inputs
Reaction time of signal out-
puts
1) The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low
voltage). The signal inputs and outputs are all protected against reverse polarity.
2) Plus the output currents
3) The signal output is protected against short circuits. However, the signal output is not protected
against overloading. Constant load currents > 0.15 A may lead to impermissible heating and therefore the
destruction of the ejector.
4) Mean value
12 / 40
Symbol
Limit value
min.
typ.
T
0
---
amb
T
-10
---
Sto
H
10
---
rel
---
---
---
P
2
4.2
Air or neutral gas, 5 µm filtered, with or without oil, class 3-3-3 com-
pressed air quality in acc. with ISO 8573-1
Symbol
min.
U
22.8
SA
I
̶ ̶ ̶ ̶ ̶ —
S/A
S/A
I
̶ ̶ ̶ ̶ ̶ —
S/A
S/A
U
U
-2
OH
S/SA
U
0
OL
I
̶ ̶ ̶ ̶ ̶ —
OH
I
̶ ̶ ̶ ̶ ̶ —
OL
U
15
IH
U
0
IL
I
IH
I
IL
t
I
t
1
O
Unit
max.
50
° C
60
° C
90
% r.h.
IP65
---
6
bar
Limit values
typ.
max.
24
26.4
4)
50
120
4)
40
70
V
S/SA
2
140
-140
U
A/SA
9
5
-5
3
200
Comment
---
---
Free from condensation
± 3% FS (full scale)
---
---
Unit
Comment
1)
V DC
PELV
mA
U
= 24.0 V
S/A
mA
U
= 24.0 V
S/A
V
I
< 140 mA
DC
OH
V
I
< 140 mA
DC
OL
mA
Short-circuit-proof
mA
Short-circuit-proof
V
In reference to Gnd
DC
SA
V
In reference to U
DC
mA
mA
ms
ms
Adjustable
EN-US · 30.30.01.02636 · 00 · 01/21
3)
3)
A/
A/SA

Advertisement