5.10 Supply Voltage Display
In operating modes in which no LEDs are activated, the "Max" LED lights up briefly. This indicates a sup-
ply voltage.
5.11 Signal Type
The signal type, or the ejector switching behavior (PNP or NPN) of the electrical signal inputs and the sig-
nal output, is permanently set on the device and is therefore dependent on the ejector version.
5.12 Control Concept for NO Ejectors
"Suction" [IN1]
"Blow off" [IN2]
"Suction" state
0 bar
"Blow off" state
5.13 Control Concept for NC Ejectors
"Suction" [IN1]
"Blow off" [IN2]
"Suction" state
"Blow off" state
EN-US · 30.30.01.02636 · 00 · 01/21
1
0
1
0
-p
p
0 bar
1
0
1
0
-p
0 bar
p
0 bar
General Description of Functions