Processed Key Menus - Sony HDS-7100 User Manual

Operation software hzs-7060
Hide thumbs Also See for HDS-7100:
Table of Contents

Advertisement

Processed Key Settings

Processed Key Menus

Button
F2 (ADJ): Make settings for key
PROC
KEY
F3 (CLEAN): Toggle the clean key function
4-16
Chapter 4 Basic Operations for Switching
Processed key setting menu
Main menu
adjustment in the return processor. →
on and off.
ON: The video signal from the DME is
not cut out by the key signal, and is
added unaltered as key fill signal to the
background.
OFF: The video signal from the DME is
cut out by the key signal before being
used as the key fill signal. (Linear key)
Submenu
F2 (ADJ): Select whether to use a preset
value determined by the type of the
key signal from the DME, or a user-
adjusted value. (PRST1/VAR)
PRST1: Preset adjustment value
appropriate when using the key
signal output from the DME
(DIGITAL OUTPUTS) as key signal
VAR: User-adjusted value
When VAR is selected, the
adjustments for F3, F4 and F5 are
also possible, as follows.
F3 (Clip): Set clip level on the key
signal.
(–10.00 to +110.00)
F4 (Gain): Set key sensitivity.
(0.00 to 100.00).
F5 (Densty): Set key density.
(0.00 to 100.00)