Carrying Out Color Correction
2
3
4
7-12
Chapter 7 Color Correction
Select F4 (CLIP).
The YUV clip menu appears.
F2 (PROC): Toggle on and off the clip function.
F3 (ADJUST): Set the clip values.
F6 (UNITY): Reset all parameters.
To reset the parameters
Press F6 (UNITY) to display the reset menu, then press F2 (EXEC).
This resets all of the parameters in the YUV clip menu, and returns to the
YUV clip menu.
To cancel the reset, press EXIT and return to the YUV clip menu.
Press F2 (CLIP), to turn on the YUV clip function. (Press once more to
turn off.)
Press F3 (ADJUST), and adjust the parameters as required.
The parameter adjustment menu consists of two pages. Press F6
(CHROMA/LUM) to switch between them.