Hz Line Level Frequency Specifications; Temperature Specifications - FLIR CM94 User Manual

True rms ac/dc 2000a utility clamp meter
Table of Contents

Advertisement

7
Specifications
200.0 A
0 ~ 500 A
500 ~ 1000 A
1000 ~ 2000 A
1. Induced error from adjacent current-carrying conductors: < 0.1 A/A
True RMS crest factor < 1.4 : 1 at full scale and < 2.8 : 1 at half scale.

7.14 Hz Line Level Frequency Specifications

Range/Function
6 V
60 V
600 V
1000 V
200 A
2000 A
6 V (VFD)
60 V (VFD)
600 V (VFD)
1. VFD sensitivity linearly decreases from 10% F.S. @ 200Hz to 40% F.S. @ 400Hz
2. VFD sensitivity linearly decreases from 10% F.S. @ 200Hz to 40% F.S. @ 400Hz
3. VFD sensitivity linearly decreases from 10% F.S. @ 200Hz to 40% F.S. @ 400Hz
Accuracy: ± (0.1% + 4 digits)

7.15 Temperature Specifications

Range
-50 ~ 1000℃
-58 ~ 1832℉
1. Supplied thermocouple is rated for -4 ~ 482°F (-20 ~ 250°C) only, and therefore not rated for the
entire specified temperature range of the meter.
2. Assumes meter interior and ambient temperature have reached stable isothermal stage for cor-
rect junction voltage compensation. Does not include error introduced by thermocouple probe.
#NAS100019; r. AC/59959/59961; en-US
1
2
3
1
40 Hz ~ 50 Hz and 60 Hz~
400 Hz
Sensitivity (sine RMS)
2 V
20 V
100 V
600 V
10 A
40 A
1 V ~ 2 V
6 V ~ 20 V
60 V ~ 200 V
Accuracy
± (0.3% + 4 digits)
± (0.3% + 6 digits)
± (2.5% + 5 digits)
± (3.0% + 5 digits)
± (3.5% + 5 digits)
Unspecified
Frequency Range
40 Hz ~ 1999 Hz
20 Hz ~ 400 Hz
10 Hz ~ 400 Hz
2
27

Advertisement

Table of Contents
loading

Table of Contents