Nortel Meridian 1 Mini-Carrier Remote Description, Installation, And Maintenance page 91

Table of Contents

Advertisement

Figure 37
SET ESAM: SHOW SLOT PARAMETERS screen
Current Cards in System:
Slot 1 Existing Card Type - XDLC
Slot 2 Existing Card Type - None
Slot 3 Existing Card Type - None
Slot 4 Existing Card Type - None
Slot 5 Existing Card Type - None
Slot 6 Existing Card Type - None
Slot 7 Existing Card Type - None
Slot 8 Existing Card Type - XUT
Slot 9 Existing Card Type - None
Slot 10 Existing Card Type - None
ESAM Setup Menu:
1 - System Parameters
2 - Show Slot Parameters
3 - Set Slot Parameters
4 - Phone Parameters
5 - XUT Parameters
6 - Trunk Parameters
8 - Quit (No Save)
9 - End (Save)
Figure 38
SET ESAM: SET SLOT PARAMETERS screen
Slot Location Setup Menu:
1 - Change XDLC Slot Location
2 - Change XUT Slot Location
9 - Quit
2
Show Slot Parameters - This variation of the SET ESAM
command shows the type of line card in each slot. Its display is similar
to Figure 37.
3
Set Slot Parameters - This variation of the SET ESAM
command allows the user to change the type of line card in each slot. Its
display is similar to Figure 38.
4
Phone Parameters - This variation of the SET ESAM command
allows the user to change the functionality of the telephone on any one of
the sixteen ports. Its display is similar to Figure 39.
Mini-Carrier Remote Description, Installation, and Maintenance
Installation and configuration
Page 91 of 150