5.2 Connecting to the Power Source
5.2.1 The Electrical connection must be made by a licensed electrician
5.2.2
The power outlet socket on the machine should be available.
5.2.3 Plug the machine to a grounded socket.
5.2.4 Main voltage of the machine is optional as 230 V 50 Hz or 400 V 50 Hz.
5.2.5 Maket he electrical socket connections after positioning the MAIN SWITCHI on the machine to 0.
5.2.6 Maket he machine connections according to the electric schema.
5.2.7 The saw direction of rotation should be controlled based on the direction rotation label on the machine (by being
used a device that is proper to the saw direction of rotation control)
5.2.8 In the cases that the saw direction of rotation is adverse, the electrical power cable connections should be
reviewed by authorized and licenced electrician and the connections should be corrected.
5.2.9 Check the supply voltage. The source voltage must be in accordance with the data
on the machine's label.
6. MACHINE SAFETY INFORMATION
6.1 It is not allowed to operate the machine with the protective cover and other protective equipment removed.
6.2 Lifting, installation, electric, pneumatic maintenance of the machine should be carried out by qualified personnel only.
6.3 Routine maintenance and scheduled maintenance should be carried out by qualified personnel after unplugging
machine and disconnecting the air supply first.