8.4
Adjust the air pressure (pneumatic systems)
8.4.1 Pull up pressure adjustment valve. Set adjustment
valve to the desired value on manometer by turning it
clockwise or counter clockwise. Then lock the valve by
pressing it down.
8.4.2 Set the air pressure between 6 and 8 BAR. If air
pressure drops below the stated values, accessories
operating with pneumatic power do not work.
8.4.3 Conditioner unit accumulates the water in the air in the
collection container so that it won't damage pneumatic
components. At the end of the working day, empty the
accumulated water by opening water discharge valve
under the collection container
8.4.4 In order to put oil to the oil tank, remove the reservoir
by turning. Oils recommended by the manufacturer
are; ; TELLUS C10 / BP ENERGOL HLP 10 / MOBIL
DTE LIGHT / PETROL OFİSİ SPINDURA 10.