3.1.10 Service screen

Operating sequences
Parameter setting
SIJECT 16i Operation Manual
Fig 3-25
Service screen 1
Press this key to enter Service screen. See Fig 3-25 Service screen 1.
On service screen, input password 2 (2000) before any parameter setting.
Then, confirm your entry by "Enter" key.
See Fig. 3-25 Service screen 1 --- parameter setting.
Carriage retract mode (CarRetMod)
position mode or time mode.
Photo sensor mode (CycSenNSTD)
normally open mode or normally close mode.
Lubrication error (LubErrNSTD)
as normally open mode or normally close mode.
Fast mold open (FastMldOpn)
special mode.
Motor protection (MotStrPro)
there is delay time during motor star triangle startup. Motor protection can
also be deselected.
Special function 1 (SpecSel 1)
Special function 2 (SpecSel 2)
Number of screw cams (ScrewCam)
screw during screw speed measurement. Range: 1 255.
Motor shut-down when alarm occurs (Motor Shut)
alarm, the time passing by from alarm occurring to motor shut. Range:
30~999s.
Heat off when alarm occurs (Heat Off)
when there is alarm.
SIJECT OP15B Screens
Carriage retract can be set as
Photo sensor can be set as
Contactor in alarm circuit can be set
It can be set as normal mode or
Motor protection can be selected, i.e., if
Spare.
Spare.
The cam numbers set on the
Select Heat On or Heat Off
When there is
3-25