Siemens SIJECT 16i Operation Manual page 58

Hide thumbs Also See for SIJECT 16i:
Table of Contents

Advertisement

SIJECT OP15B Screens
3-32
Secondly, select valve type, such as pressure valve; then select valve limit,
such as maximum:
Choose "Max." in valve limit, and change its value by softkey:
1.
Use cursor key
2.
Press selection key
3.
Use cursor key
4.
Confirm it with Enter Key;
5.
Press softkey F3 " " to increase the "Max."; or use softkey F4"-" to
reduce "Max.". This
amperemeter.
After finishing the adjustment of the valves. Select OFF to stop valve
adjustment.
Lastly, check the adjustment result:
In the "Force Output" mode, implement the "Pressure Test":
1.
Press softkey F2 "Force Output", and the upper box will backlight;
2.
Set the value of 140bar in Pressure Test;
3.
Check if the external amperemeter reaches the maximum, such as
1Amp.
or
to enter valve adjustment selection;
, and cursor moves to left;
or
to select "Max.";
process
can be
SIJECT 16i Operation Manual
observed
by external