Operating sequences
SIJECT 16i Operation Manual
Fig 3-11
Monitoring screen 1.2 – purge screen
Press Monitoring key to enter Monitoring screen where current system
pressure and flow of the machine can be monitored. The real time status of
the machine is also displayed, such as mold open/close, injection and core
in/out, etc. see Fig. 3-9, Monitoring screen 1.
On this screen, following parameters can be monitored: Positions (mold
position, screw position and ejector position), speed (screw rotation
speed), quantity (part count, today's production), time (cycle time) and
mold number (recipe number).
Press soft key F1
Monitoring screen 1.1 --- event record screen. If there is event message
during operation, then indicator
check this screen and take correction activities. It is different from alarms.
Press soft key F2
screen and the purge time or purge counting can be set. Then press
softkey F1 "Start purge" to start the purge operation. Or, press F2 "Stop
purge" to stop the purge operation. See Fig. 3-11, Monitoring screen 1.2 ---
purge screen.
Press soft key F3 "Manual lubrication" to carry out lubrication manually.
During lubrication, the indicator
users that the machine is now under lubrication.
Notice
During manual lubrication, related parameters should be preset on service
screen. See section 3.1.10 "Service screen – Lubrication setting".
to display event record screen. See Fig. 3-10,
(see table 3-1) is flashing. Users should
on monitoring screen 1 to enter the purge
(see table 3-1) is flashing to inform
SIJECT OP15B Screens
3-11