2.7 Operating mode keys

General
Semi-Auto mode key
Timer-Full-Auto mode key
Photo Sensor Full-Auto mode key
SIJECT 16i Operation Manual
You can start the machine in different modes: Semi-Auto mode, Timer-Full-
Auto mode, Sensor-Full-Auto mode, Manual mode and Mold adjustment
mode.
When machine starts for the first time, select Semi-Auto mode, Timer-Full-
Auto mode, Sensor-Full-Auto mode. The function is actuated only after the
Run key is pressed, and the safety door opens hereafter. For Manual mode
and mold adjustment mode, it is not necessary to use Run key.
First set all the recipe data, then press this semi-auto mode key and wait
for the LED on.
Press the RUN key
Another cycle should be started by pressing RUN key
safety door is opened/closed once.
Lubrication can be done automatically if the machine has run more times
than the lubrication counter setting number.
Set all the parameters necessary (including total cycle time), press this
Timer-Full-Auto mode key and wait for the LED on.
Press the RUN key
the cycle automatically, until the set product quantity has been reached.
Then the machine stops and LED off.
Lubrication can be done automatically if the machine has run more times
than the lubrication counter setting number.
Set all the parameters necessary (including part counter), press this
Sensor-Full-Auto mode key and wait for the LED light on.
Press the RUN key
the cycle automatically, until the set product quantity has been reached.
Then the machine stops and LED off.
During this process, when a cycle is finished, the sensor will check whether
the product has fallen down. If it is OK, the next cycle will run successfully.
Otherwise, alarm is on and the machine will stop.
Lubrication can be done automatically if the machine has run more times
than the lubrication counter setting number.
. Machine will start automatically for one cycle.
to start the system. The machine will execute
to start the system. The machine will execute
Operator panel keys
again, or