Installation Of Cassette Type - GREE ELECTRIC GUHD09NK3CO Service Manual

U-match series a/a dc inverter air conditioners
Table of Contents

Advertisement

U-Match Series DC
Inverter Service Manual
No folding of drain hose inside the indoor unit. (Refer to Figure 1-2-11)

1.3 Installation of Cassette Type

1.3.1 Before Installation
please immediately report to the transport company or equipment company in writing.
After receiving the machine, please check the unit and accessories in reference to the packing list. Ensure
accessory parts are correct.
Determine the correct handling route and methods, thus to avoid damaging the unit or causing possible hazard.
For the sake of protection and safety, it is suggested to move the unit with the packaging box. Even though it is not
permitted to do like this under special occasions, do not remove the packaging box, thus to avoid loosening or falling
during handling.
Confirm if the installing foundation is solid. When this unit is to be installed on the metal section of the
building, make sure that the electrical insulation must comply with applicable standards.
1.3.2 Installation Site
though all the room.
Make sure that the installation had accord with the requirement of the schematic diagram of installation spaces.
Select the place where can stand 4 times of the weight of the indoor unit and would not increase the operating
noise and oscillate.
The horizontally of the installation place should be guaranteed.
Select the place where is easy to drain out the condensate water, and connect with outdoor unit.
Make sure that there are enough space for care and maintenance. Make sure that the weight between the indoor
unit and ground is above 2300mm.
When installing the steeve bolt, check if the install place can stand the weight 4 times of the unit's. If not,
be installed in laundry.
Cautions:
There will be lots of lampblack and dust stick on the acentric, heat exchanger and water pump in dining room and
kitchen, which would reduce the capacity of heat exchanger, lead water leakage and abnormal operation of the water
pump.
The following treatment should be taken under this circumstance:
81
Figure 1-2-10
Figure 1-2-11
Figure 1-2-12

Hide quick links: