GREE ELECTRIC GUHD09NK3CO Service Manual page 107

U-match series a/a dc inverter air conditioners
Table of Contents

Advertisement

Table3 This section is applicable to the electric control box of the GUHD09NK3CO/GUHD12NK3CO A/A DC
inverter air conditioners
NO
Running Status
1
Compressor started
2
Defrosting
3
Anti-freezing protection
4
IPM protection
5
Over-current protection
6
Heat exchanger overload protection
7
Discharge protection
8
Compressor overload protection
9
Power protection
10
Module overheating protection
11
EEPROM reading error
12
Low voltage protection
13
High voltage protection
14
PFC over-current protection
15
Unmatched indoor and outdoor units
16
Limited frequency(current)
17
Limited frequency (discharge)
18
Limited frequency (overload)
19
Reduced frequency (anti-freezing)
Outdoor ambient temperature
20
sensor error
21
Outdoor pipe temperature sensor error
Outdoor discharge
22
temperature sensor error
23
Up to the startup temperature
Limited frequency
26
(module temperature)
28
Limited frequency (power)
31
Communication normal
32
Communication error
Indoor ambient temperature
33
sensor error
34
Indoor pipe temperature sensor error
Red Lamp
Yellow Lamp
Flash once
Flash twice
Flash 3 times
Flash 4 times
Flash 5 times
Flash 6 times
Flash 7 times
Flash 8 times
Flash 9 times
Flash 10 times
Flash 11 times
Flash 12 times
Flash 13 times
Flash 14 times
Flash 16 times
Flash once
Flash twice
Flash 3 times
Flash 4 times
Flash 6 times
Flash 5 times
Flash 7 times
Flash 8 times
Flash 11 times
Flash 13 times
U-Match Series DC
Inverter Service Manual
Green Lamp
Displayed
E2
E5
E5
/
E4
E5
E5
E5
E5
E5
E5
E5
/
/
/
/
/
F3
F2
F4
/
/
/
Flash continuously
/
Black out
E6
F0
F1
104