GREE ELECTRIC GUHD09NK3CO Service Manual page 166

U-match series a/a dc inverter air conditioners
Table of Contents

Advertisement

U-Match Series DC
Inverter Service Manual
2 . R e m o v e t h e
liquid separator
3. Remove the inlet
p i p e a n d o u t l e t
pipe of gas-liquid
separator
4. Remove the gas-
liquid separator .
5 . R e m o v e t h e
screws fixing the
compressor .
6. Remove the air
inlet pipe and the
outlet pipe of the
compressor
163
Remove the screw fixing the gas-liquid
separator.
A. Unsolder the inlet pipe and outlet pipe
of the gas-liquid separator.
B. During soldering,charge nitrogen
with pressure of 0.5±0.1kgf/cm
pressure)
C. Do not burn the surrounding material
during heating.
Remove the gas-liquid separator.
R e m o v e t h e s c r e w s f i x i n g t h e
compressor .
A. Unsolder the inlet pipe and outlet pipe
of the gas-liquid separator.
B. During soldering,charge nitrogen
with pressure of 0.5±0.1kgf/cm
pressure)
C.Do not burn the surrounding material
during heating.