GREE ELECTRIC GFH09K3AI Operating And Installation Instruction Manual

Dc inverter ducted air-conditioning unit
Hide thumbs Also See for GFH09K3AI:

Advertisement

Operating and Installation Instructions Manual
Unit Model:

indoor unit

GFH09K3AI
GFH12K3AI
GFH18K3AI
GFH24K3AI
GFH36K3AI
GFH42K3AI
GFH48K3AI
GFH36K3AI
GFH42K3AI
GFH48K3AI
GFH60K3AI
GREE ELECTRIC APPLIANCES INC
Thanks for your selection of Gree Ducted Air-Conditioning Unit. Before use, please read this
instruction manual carefully and keep it properly to ensure correct use of this machine.
DC Inverter Ducted Air-Conditioning Unit
GFC09K3AI
GFC12K3AI
GFC18K3AI
GFC24K3AI
GFC36K3AI
GFC42K3AI
GFC48K3AI
GFC36K3AI
GFC42K3AI
GFC48K3AI
GFC60K3AI
(2.6-16kW)
GUHD09NK3AO
GUHD12NK3AO
GUHD18NK3AO
GUHD24NK3AO
GUHD36NK3AO
GUHD42NK3AO
GUHD48NK3AO
GUHD36NM3AO
GUHD42NM3AO
GUHD48NM3AO
GUHD60NM3AO

outdoor unit

GUCD09NK3AO
GUCD12NK3AO
GUCD18NK3AO
GUCD24NK3AO
GUCD36NK3AO
GUCD42NK3AO
GUCD48NK3AO
GUCD36NM3AO
GUCD42NM3AO
GUCD48NM3AO
GUCD60NM3AO
.
OF ZHUHAI

Advertisement

loading

Summary of Contents for GREE ELECTRIC GFH09K3AI

  • Page 1: Indoor Unit

    GUHD48NM3AO GUCD48NM3AO GFH60K3AI GFC60K3AI GUHD60NM3AO GUCD60NM3AO GREE ELECTRIC APPLIANCES INC OF ZHUHAI Thanks for your selection of Gree Ducted Air-Conditioning Unit. Before use, please read this instruction manual carefully and keep it properly to ensure correct use of this machine.
  • Page 2: Table Of Contents

    Safety Considerations Wire controller (standard fitting) Turning On/Off Unit Component Description Temperature Setting Fan Control Sleep Function Setting Operating Mode Setting Timing Setting Operating Operating Energy Saving Setting Instructions Instructions for Line Display of Outdoor Ambient Temperature Controller Power-fail Memory Function Setting Debug Function Failure Display Operation of Remote Controller...
  • Page 3: Safety Considerations

    Safety Considerations Please read this manual carefully before use and operate correctly as instructed in the manual. You are specially warned to note the two symbols below.: WARNING! A symbol indicating that improper operation might cause human death or severe injury WARNING! A symbol indicating that improper operation might cause human property damage.
  • Page 4: Wire Controller (Standard Fitting)

    Wire controller (standard fitting) Composition of wire controller Failure status display 1 Timing display Sleep st atus display Fan speed display (Auto, High speed, Medium speed, Low speed) Mode key Defros ting st atus display Se t temperature increase key Energy saving st atus display Se t temperature decr ease key Se t temperature display...
  • Page 5: Turning On/Off Unit

    Turning ON/OFF unit Pr ess t he ON/OFF ke y, then the unit shall star t up. Pr ess t he ON/OFF key again, then the unit shall shut off. Fan contr ol (the figur es show the r elevant display ar eas) If the fan control key is prssed consecutively, the fan speed shall changes as per t he following sequence: Low speed...
  • Page 7 Timer Setting When the unit is shut off, timing start can be set; After the unit is started up, timing shutoff can be set. After the "TIMER"key is pressed, the unit enters the timing set status and the word "TIMER" flashes on the display.
  • Page 8 The indoor room temperature is measured at the wire controller when the mode is 'heating' or 'auto'. At other modes is measure at the air intake(Now the OUT ENV area displaus 03) ,The default is 03.
  • Page 9: Failure Display

    Failure Display When there is failure in the unit operation, “ERROR” will flash on the LCD of the wire controller and the code of fai- lure will also be displayed. When there are multiple failures at the same time, the codes of failures will be displayed one after one on the wire controller.
  • Page 10 Definition of Indicator Main Control Panel of DC Inverter General Outdoor Unit Remark light black Mal. Display Remarks Mal. item LED6 LED5 LED4 LED3 LED2 LED1 Overvoltage protection Overheat protection of carbon fin Current sensor mal. Carbon fin sensor mal. Compressor current protection Low voltage protection Failed startup...
  • Page 11 Remarks Mal. item Communication mal. (among indoor unit, outdoor unit and manual controller Outdoor ambient sensor mal. Coil pipe inlet sensor mal. of outdoor unit Coil pipe intermediate sensor mal. of outdoor unit Coil pipe outlet sensor of outdoor unit Exhaust sensor mal.
  • Page 12 SWING...
  • Page 16 U nit Function • 7DP - Seven days programmer (Accessory not supplied) Unit off display Clock display Confirm button Increase button Decrease button Cacel/delete button Single/group button Timer/time button ON/OFF button...
  • Page 17 Note: For upper unit checks 16 lower units consecutively, there will be no more than 16 seconds delay when setting works till unit responds. Please let us know your requirement before your placing the order, for this WEEKLY TIMER will only be prepared when customer orders (communication joint with WEEKLY TIMER on manual control had been prepared).
  • Page 18 Wire controller (with week timer functions) Composition of wire controller(Accessory not supplied) Sleep st atus display 1 Timing display Mode key Fan speed display (Auto, High speed, Medium speed, Low speed) Se t temperature increase key Defros ting st atus display Se t temperature decr ease key Energy saving st atus display Fan speed key (fresh air setting)
  • Page 19 • Wire controller with week timer function,No.1-No17 is the same as front • instructions of No18,No.19: Timer setting (Fig. 15, 16, 17) The timer function of this display board is invalid when connect with the timer of the last week, the display board will be controlled by the week timer.
  • Page 20 ™ If enter into timer setting, by pressing “Mode” button to select the setting item: Day (Monday to Sunday), Segment (1-4), Timer (timer on or timer off), the Minutes and Hours of the time; By pressing “ ” “ ” buttons to adjust the setting, then press the Timer button to confirm, and press the Timer button once more to cancel the setting;...
  • Page 21 If enter into “Cancel Timer”, by pressing “ ” “ ” buttons to select Week, then press the “Timer” button to confirm, at this time, “dd” will display; or press “Timer” button to cancel the selected day, at this time “dd” will not display. At last press “ON/OFF”...
  • Page 22: Unit Function

    Unit Function Setting of Indoor Room Sensor and Checking of Outdoor Ambient Temperature 1. Setting of Double Indoor Room Sensors This series of ducted air-conditioning unit has two indoor room sensors. One is located at the air intake of the indoor unit and the other one is located inside the wire controller. User can select one from the two indoor room sensors on the basis of the engineering requirement.
  • Page 23: Indoor Side

    Air Valve Fig.24 4. The head of delivery of the condensate drainage pump can reach 1.1m, so that the engineering installation is very convenient and prompt. GFH09K3AI GFC09K3AI GFH12K3AI GFC12K3AI Pump GFH18K3AI GFC18K3AI GFH24K3AI GFC24K3AI GFH36K3AI GFC36K3AI...