General Specifications - Renishaw ATOM DX Installation Manual

Linear encoder systems
Hide thumbs Also See for ATOM DX:
Table of Contents

Advertisement

General specifications
Power supply
5 V −5 /+10% Typically < 200 mA fully terminated
Temperature
Installation (RKLF) +10 °C to + 35 °C *
Humidity
Sealing
Acceleration
(system)
Shock
(system)
Vibration
Mass
Standard readhead 3.2 g
Top exit readhead 2.9 g
Cable
Cabled connector options
Top exit readhead connector
Typical sub-divisional error 
20 µm version < ±75 nm
(SDE)
40 µm version < ±120 nm
* To limit maximum tension in the scale (CTE
substrate
CAUTION: Renishaw encoder systems have been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance.
In particular, attention to shielding arrangements is essential.
ATOM DX
linear installation guide
Power from a 5 Vdc supply complying with the requirements for SELV of standard IEC 60950-1
Ripple 200 mVpp maximum@frequency up to 500 kHz
Storage −20 °C to +70 °C
Operating 0 °C to +70 °C
95% relative humidity (non-condensing) to IEC 60068-2-78
IP40
Operating 400 m/s², 3 axes
Operating 1000 m/s², 11 ms, ½ sine, 3 axes
Operating 100 m/s² max @ 55 Hz to 2000 Hz, 3 axes
Cable 18 g/m
10 core, high flex, EMI screened cable, outside diameter 3.5 mm maximum
Flex life > 20 × 10
cycles at 20 mm bend radius, maximum length 3 m
6
(Extension cable up to 25 m when using Renishaw approved extension cable)
UL recognised component
Top exit cables available in lengths from 0.5 m to 3 m with 15-way D-type or 10-way JST (SH) connector options.
9-way D-type
15-way D-type (standard and alternative pin out)
10-way JST (SH)
10-way JST (SUR)
− CTE
) × (T
− T
) ≤ 550 μm/m where CTE
scale
use extreme
install
= ~ 10.1 μm/m/°C
scale
34

Advertisement

Table of Contents
loading

Table of Contents