RTLF / RKLF tape scale
(continued)
RTLF ledge or dowel mounting
Suitable for:
 RTLF tape scale < 500 mm long
Required parts:
 Appropriate length of RTLF scale
 Appropriate cleaning solvents
('Storage and handling', page 3)
 Datum clamp (A-9585-0028)
 Loctite
435
(P-AD03-0012)
®
ATOM DX
linear installation guide
('RTLF installation drawing', page 5)
Optional parts:
 Renishaw scale wipes (A-9523-4040)
 Loctite
435
dispensing tip (P-TL50-0209)
®
 End cover kit (A-9585-0035)
 Reference mark deselection stickers (A-9402-0049 for a sheet of 20)
 Lint-free cloth