Command Set
VU
USAGE
SYNTAX
xxVUnn or xxVU?
PARAMETERS
Description
xx
nn
Range
xx
nn
Units
xx
nn
Defaults
xx
nn
DESCRIPTION
This command set the value of MaximumVelocity in full-step/second.
RETURNS
The value of Maximum Velocity in full-steps/second
REL.
VA
COMMANDS
AC
AU
EXAMPLE
17VU200
17VA?
set maximum velocity
IMM
MIP
[ int ]
-
Controller number
[ float ]
-
Velocity
-
0 to 255
0 to the maximum programmed
-
value in VU command or xxVA? to
read current setting
-
None
-
Full-steps/second
missing:
none
out of range:
none
missing:
Error 37, Parameter Missing
out of range:
Error 7, Parameter Out of Range
Error 230, Command not allowed
during motion
-
Maximum Velocity
-
Acceleration
-
Maximum Acceleration
|
Sets the Velocity for controller 17 to 200 full-
steps/second
|
Reads back the value of Velocity