Newport NewStep NSA12 User Manual page 65

Actuator and motion controller
Table of Contents

Advertisement

Command Set
SR
USAGE
SYNTAX
PARAMETERS
Description
Range
Units
Defaults
DESCRIPTION
RETURNS
REL.
COMMANDS
set right travel limit
IMM
MIP
xxSRnn or xxSR?
xx
[ int ]
-
nn
[ int ]
-
xx
-
nn
-
xx
-
nn
-
xx
Missing:
out of range:
nn
missing:
out of range:
This command will set the value of the negative software limits.
NOTE: The value of positive software limit should be larger
than the value of the Negative Software limit.
If the "?" sign takes the place of nn value, this command reports
the value of the Positive Software limit.
SL
-
Negative Software Limit
PA
Absolute Move
Controller number
Positive software limit
0 to 255
-60000 to 1200000
None
Micro-steps
None
None
Error 37, Parameter Missing
Error 7, Parameter Out of
Range
Error 230, Command not
allowed during motion
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Newstep nsc100