Newport NewStep NSA12 User Manual page 47

Actuator and motion controller
Table of Contents

Advertisement

Command Set
AU
USAGE
SYNTAX
PARAMETERS
Description
Range
Units
Defaults
DESCRIPTION
RETURNS
REL.
COMMANDS
set maximum acceleration
IMM
MIP
xxAUnn or xxAU?
xx
[ int ]
-
Controller number
nn
[float ]
-
Acceleration value
xx
-
0 to 255
0 to 500 or xxAU? to read current
nn
-
setting
xx
-
None
nn
-
Full Steps/second
xx
missing:
None
out of range:
None
nn
missing:
Error 38, Parameter missing
out of range:
Error 7, Parameter Out of Range
Error 230, Command not allowed
during motion
This command is used to set the maximum acceleration value for the
actuator. It's execution is immediate. However, if there is motion in
progress the command is ignored.
If the "?" sign takes the place of nn value, this command reports the
current setting.
AC
-
set acceleration and deceleration
PA
execute an absolute motion
PR
execute a relative motion
2
47