Floor Level Guideline Adjustments - Braun VISTA Series Installation & Service Manual

Commercial wheelchair lift
Hide thumbs Also See for VISTA Series:
Table of Contents

Advertisement

Must make full contact.
D
Unfold/Down and Up/Fold Microswitches: The
Unfold/Down and Up/Fold microswitches (limit
switches) are located in the pump side tower.
Adjustment: Use a 7/16" socket wrench to turn
the two 1/4"-20 x 5" hex bolts to reposition the limit
switches. Adjust these microswitches as outlined
below and on Microswitch Adjustment Instructions
decal 24490 (posted on tower).
W ARNING
Improper microswitch
adjustment may
result in serious
bodily injury and/or
property damage.
Page 28

Floor Level Guideline Adjustments

OK
Stop Block Guideline
Stop blocks must make
full contact with the
edge of the vertical arms.
Stop Block
Vertical Arm
Up/Fold
Microswitch:
Turn adjustment
bolt counter-
clockwise to stop
platform raise
function sooner.
Turn adjustment
bolt clockwise to
allow platform to
raise further.
Wrong
Floor Level Guideline Adjustments: The Unfold/
Down and Up/Fold microswitches control platform
and bridge plate positioning. Ensure floor level
adjustments are correct as outlined on page 29A.
Platform Angle Adjustments: Check platform
angle as outlined on pages 26 and 27 when adjust-
ing bridge plate positioning.
C
Gap not permitted.
E
Unfold/Down
Microswitch:
Turn adjustment
bolt clockwise to
stop platform
unfold function
sooner.
Turn adjustment
bolt counter-
clockwise to
allow platform to
unfold further.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista vl917ib

Table of Contents