30
Introductory Recording Tutorial
EQ
02R Getting Started Guide

Using the EQ Library

The EQ Library is used to access and store EQ settings—stored as
programs. There are 32 preset programs (1 to 32) for you to recall and 96
user programs (33 to 128 plus UNDO) for you to store your own EQ
settings. First you need to know how to recall EQ programs, then how to
store your own.
Note: The programs 33 to 40 contain preset programs and are listed in the "EQ
Programs" on page 54 of the User's Guide. However, you can store your own
settings to these programs.
Recalling an EQ Program
1. Use the [EQ] button to locate the EQ 2/2 page shown below.
The top of the page shows the EQ curve for the selected channel and a level
meter for the channel and its adjacent pair.
2. Press the [SEL] button for MIC/LINE 1.
This step is required only if you have selected another channel.
3. Select the RECALL icon with the CURSOR buttons.
In order to scroll through the list of EQ programs, the cursor must be on the
STORE, RECALL, CLEAR, COPY, or PASTE icons.
4. Use the encoder wheel to select an EQ program.
As you scroll through the EQ programs, the EQ curve for each program is
displayed to the left of the list.
5. Press the [ENTER] button.