• Details of the GSD file
Parameter
#Profibus_DP
GSD_Revision
Vendor_Name
Model_Name
Revision
Ident_Number
Protocol_Ident
Station_Type
FMS_Supp
Hardware_Release
Software_Release
9.6_supp
19.2_supp
93.75_supp
187.5_supp
500_supp
1.5M_supp
3M_supp
6M_supp
12M_supp
MaxTsdr_9.6
MaxTsdr_19.2
MaxTsdr_93.75
MaxTsdr_187.5
MaxTsdr_500
MaxTsdr_1.5M
38
PROFIBUS DEVICE DATA
Value
2
"Mitsubishi Electric"
"FR-A8NP"
H0EA8
0
0
0
1
1
1
1
1
1
1
1
1
15
15
15
15
15
25
Description
File header
ID version of GSD file
*2
Manufacturer name
Product name
Product version
Device number
PROFIBUS-DP is 0 fixed.
DP slave is 0 fixed.
FMS (Field-Bus Message Specifications) not supported.
Hardware version
Software version
Communication speed 9600 bps support
Communication speed 19.2 Kbps support
Communication speed 93.75 Kbps support
Communication speed 187.5 Kbps support
Communication speed 500 Kbps support
Communication speed 1.5 Mbps support
Communication speed 3.0 Mbps support
Communication speed 6.0 Mbps support
Communication speed 12.0 Mbps support
Longest time 15 bit times at communication speed 9600 bps
Longest time 15 bit times at communication speed 19.2 Kbps
Longest time 15 bit times at communication speed 93.75 Kbps
Longest time 15 bit times at communication speed 187.5 Kbps
Longest time 15 bit times at communication speed 500 Kbps
Longest time 25 bit times at communication speed 1.5 Mbps
*1