Hot-Plug Drive Led Definitions - HPE ProLiant DL325 Gen10 Plus User Manual

Hide thumbs Also See for ProLiant DL325 Gen10 Plus:
Table of Contents

Advertisement

Item
LED
1
Fault
\Locate
2
Online
\Activity

Hot-plug drive LED definitions

Item
LED
1
Locate
Status
Solid amber
Solid blue
Flashing amber/blue
(1 flash per second)
Flashing amber
(1 flash per second)
Solid green
Flashing green
(4 flashes per second)
Flashing green
(1 flash per second)
Off
Status
Definition
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an update.
Definition
The drive has failed.
The drive is operating normally and being identified by a
management application.
The drive has failed, or a predictive failure alert has been received for
this drive; it also has been identified by a management application.
A predictive failure alert has been received for this drive. Replace the
drive as soon as possible.
The drive is online and has no activity.
The drive is operating normally and has activity.
The drive is doing one of the following:
Rebuilding
Performing a RAID migration
Performing a strip size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
Spare part activation
The drive is not configured by a RAID controller or a spare drive.
Table Continued