Automatic Stop System; Care And Maintenance; Help With Faults; Warranty Conditions - Lavor Tormenta Translation Of The Original Instructions

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
EN
connected to the terminal wich is marked with the
letter N or coloured Black.
Safety points for rewireable or moulded plug:
The mains lead of this appliance may be already fitted
with a BS1363 13A plug.
-
If your socket outlet is not suitable for the plug,
then the plug must be removed (cut off if it is a
moulded on plug), the flexible cord insulation
should be stripped back as appropriate and a suit-
able 3 pin plug fitted.
WARNING: Dispose of a plug that has been cut
from the power supply cord, as such a plug is haz-
ardous if inserted in a live 13A socket outlet else-
where in the house.
-
Should the fuse need to be replaced an ASTA
marked fuse, approved to BS1362, of the same
rating must be used.
-
Always replace the fuse cover after fitting a fuse.
The plug must NOT be used if the cover is omitted
or lost until a replacement is obtained.
-
Make certain that only the correct fuse cover is
used and fitted.
-
For plugs with detachable fuse cover the replace-
ment must be the same as the colour insert in the
base of the plug, or as directed by the embossed
wording on the base of the plug.
-
If the detachable fuse cover is lost a replacement
may be purchased from a Service Centre.
Information for supply may also be obtained
from the plug manufacturer.
230-240V
100-120V
1,5 mm
2
14 AWG
2,5 mm
12 AWG
2
max 20 m
max 30 m
18
PLEASE NOTE: This water cleaner is equipped with
the A.S.S. (Automatic Stop System), which stops the
machine during the bypass phase. To start the water
cleaner, it is therefore necessary to set the switch on
position (I)"ON"; after that press the pistol trigger:
the Automatic Stop System will start the machine
and will stop it automatically when the trigger is
released. It is advisable to put on the safety of the
pistol trigger whenever the machine is stopped, in
order to avoid unintentional starting.
• Any automatic start of the machine without
pressing the gun trigger is attributable to air
bubbles in the water or other similar phenom-
ena which do not imply the existence of any de-
fects in the machine.
• Do not leave the appliance unattended during
the standby for more than 5 minutes. Contrarily,
for the safety of the appliance it is necessary to
re-turn the switch into the (0) OFF position.
• Please check that the coupling of the high pres-
sure hose with the appliance and the gun sup-
plied as standard equipments made correctly,
that is to say without any water leak.
>

CARE AND MAINTENANCE

The unit is maintenance-free.
Disconnect the appliance from the power sup-
ply network before making any maintenance
and cleaning operation.
>

HELP WITH FAULTS

Appliance does not work
• Check whether the voltage shown on the rat-
ing plate corresponds to that of the power
source.
• Check the connector cable for damage.
Appliance does not reach operational pressure
• Vent the appliance: allow the pump to operate
without the high-pressure hose until water ap-
pears at the high-pressure outlet without any
(if fitted)

Advertisement

Table of Contents
loading