Arms Error Messages - GRAPHTEC FCX4000 Service Manual

Hide thumbs Also See for FCX4000:
Table of Contents

Advertisement

9.6

ARMS Error Messages

Error cord No.
E04001
E04002
E04003
E04007
E04009
E04010
E04011
FCX4000-UM-251-9370
LCD Display
Tilt to adjust with AXIS
ALIGNMENT is too
large.
It is over the setting
range of the distance
adjust.
The registration marks
printed position is not
matching to the output
data.
Some of hairlines
are printed near the
registration mark.
The registration marks
were not printed on the
10 mm from the media
edge.
Failed to adjust the
sensor level.
Test pattern plotting
position is not within the
plotting area for sensor
position adjustment.
It has exceeded
detection area while
detecting the registration
mark.
It has exceeded
detection area while
detecting the registration
mark for +X direction.
It has exceeded
detection area while
detecting the registration
mark for -X direction.
9-11
9
Cause
Reload the media.
Confirm the printed
registration mark positions are
matching to the output data.
Confirm no object is printed
near the registration mark.
There is not enough margin
for the registration mark from
media edge.
Reflection of media is too
high.
Use low reflection of media.
Use low reflection of laminate
if the media is laminated.
Plot the test pattern to the
center of plotter.
Confirm media position that is
inside of cutting area.
Confirm media position that is
inside of cutting area.
Confirm media position that is
inside of cutting area.
TROUBLESHOOTING