3.3.2 Installation dimensions

The following figures show the dimensions required installing the controller.
For the placement of the controller on its side (the horizontal installation), two stacks is permitted.
Horizontal installation
145mm
170mm
Vertical installation
150mm
Fig.3-6: Installation dimensions
CAUTION
CAUTION
Air intake
When installing the controller vertically, ensure that the air intake is at the bottom as
illustrated in
Fig.
3-6.
Fixing installation section sure for prevention from the fall, when using the controller
placing vertically. The reference figure of the metal plate for fixing is shown in
7.
You should install the metal plate for fixation to the controller with M4 x 8 or the
shorter screw. The screw projection length inside the controller (side board
thickness is 1.2 mm) surely makes 6.8 mm or less.
145mm
150mm
50mm
Air intake
Outside dimensions/Installation dimensions 3-53
3 Controller
20mm
Fig. 3-

Hide quick links: