5. Completely empty the juice collector over a large bowl. Fold the juice spout
down to the open position. Thereafter, you can rinse the juice outlet via a jet of
running tap water.
6. Ensure that the juice outlet is clear again and the juices will flow freely. Rinse the
filter basket and juicing cone. Thereafter, thoroughly dry the exterior of the juice
collector and the interior of the juicing cone. If required, clean the drive shaft
too for avoiding that the juicing cone sticks to the drive shaft.
7. Re-assemble the juicing system (see: 'Assembling the Appliance'). Thereafter you
may continue juicing as usual.

SOLVING PROBLEMS

If any problems occur during operation, you will find solutions in this section.
– Before starting your troubleshooting and making any mani-
WARNING
pulations at the appliance, always unplug the appliance!
Problem
Emergency stop required?
You find it difficulty to
insert the juice collector
into the top plate of the
motor base.
The juicing cone does not
completely slip down on
the drive shaft.
The fruit dome cannot be
lowered correctly onto the
juicing cone.
Possible Reasons
The juice collector is not in
correct orientation.
A small gap of approx.
1/2 cm of free space
must be left.
There are some residues
of juice and/or pulp sti-
cking to the interior of the
juicing cone.
The appliance is not
assembled correctly.
The Easy Solution
Unplug the appliance.
The juice spout must be inserted in the groove of the top
plate. Turn the juice collector accordingly.
Hold the juice collector somewhat inclined for inserting
the juice collector at the front side (juice spout) first.
Then, without violence press the juice collector down all
over, until it settles without any gaps on the rim of the
top plate. If required, turn the juice collector a little to
and fro to make it settle correctly within the top plate.
There must be a small gap between the strainer of the
filter basket and the juicing cone for allowing the juicing
cone to turn during operation. This is correct.
Clean the interior of the juicing cone and the drive shaft. Do
not attempt to press the juicing cone down with violence.
Ensure that the juice collector is engaged correctly at the
top plate of the motor base. Ensure that only one sin-
gle filter basket is inserted in the juice collector.