Clearing The Juice Outlet Of The Juice Collector - Gastroback ADVANCED PRO S Operating Instructions Manual

Citrus juicer
Hide thumbs Also See for ADVANCED PRO S:
Table of Contents

Advertisement

Available languages

Available languages

5. Ensure that the juice will flow through the juice outlet, when opening the drip-stop
feature by pushing down the juice spout. If the juice outlet is clogged, remove
the obstacle (see below: 'Clearing the Juice Outlet of the Juice Collector').
6. After removing the juicing cone, always ensure that the interior of the juicing cone
is completely clean and dry, before re-assembling the juicing cone. Otherwise,
liquids may run onto the motor base or the juicing cone sticks to the drive shaft.
7. Re-assemble the juicing system completely and correctly (see: 'Assembling the
Appliance'). Thereafter, you may continue juicing.

CLEARING THE JUICE OUTLET OF THE JUICE COLLECTOR

CAUTION
ner of the filter basket, the juice collector must be emptied. Do not let the juice level
rise up to the rim of the filter basket! Otherwise the juice could splash during juicing
and run or drip on or under the motor base, causing risk of electric shock and fire.
1. If the juice spout is folded up to the closed position, place a suitable large juice
vessel (minimum volume: 1/2 litres) under the juice spout. Then push the juice
spout down for opening the juice outlet, letting the juice flow out. If the juice
does not flow, fold the juice spout up to the closed position again. Remove the
juice vessel.
2. Ensure that the appliance is unplugged. Then remove the fruit dome from the
press arm (see: 'Disassembling the Appliance').
CAUTION
to remove the juicing cone and filter basket, before removing the juice collector.
Otherwise the juice could drip or run onto the motor base. If required, use a spoon
or little ladle for taking out some juice, before removing the juice collector from the
appliance. Handle the juice collector with special care, when pulling the juice
collector out of the top plate of the motor base, to avoid spilling the juice.
3. If the juice reached the rim of the filter basket, remove the juicing cone and filter
basket separately. Otherwise you may remove the juice collector, filter basket,
and juicing cone together (see: 'Disassembling the Appliance').
4. If required, spoon out some juice and with the juice level lowered sufficiently,
carefully pull out the juice collector (see: 'Disassembling the Appliance').
CAUTION
may have accumulated within the juice outlet via a jet of water.
EN
54
– At the latest, when the juice fills the juice collector up to the strai-
– If the juice reached the rim of the filter basket already, you need
– Do not poke in the juice outlet. Rinse any residues of pulp that

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

41150

Table of Contents