Modular power controller with overcurrent fault protection
Table of Contents

Advertisement

OUT5,���,OUT8 cooling control outputs (option)
Function
Relay
Continuous
Logic
Triac
OUT9, OUT10 alarm
Function
Relay
PORT GFW-OP
Function
PORT1 (always present)
Function
Protocol
Baudrate
Node address
Type
PORT2 (Fieldbus option)
Function
Protocol
CATEGORY OF USE
(Tab. 2 EN60947-4-3)
Trigger mode
Feedback mode
Max rated voltage
Work voltage range
Non-repetitive voltage
Rated frequency
Critical Dv/dt with output deactivated
Held nominal voltage of on the impulse
Breaking
Protection
80993B_MHW_GFW-Xtra_06-2018_ENG
Configurable (default: cooling control)
Contact NO 3A, 250V/30Vdc cosφ =1
0/2...10V (default), max 25mA short circuit protection
0/4...20mA, max. load 500ohm
isolation 500V
24Vdc, > 18V a 20mA
230V/ max 4A AC51 (1A for each channel)
Function Configurable (default alarms)
Contact NO 5A, 250V/30Vdc cosφ =1
COMMUNICATIONS PORTS
Serial comunication for KB-ADL terminal to display parameter
programming
Function Local serial communication
ModBus RTU
Settable 1200,...,115200, (default 19,2Kbit/s)
Node address Settable with rotary-switches
RS485 - isolation 1500V, double connector RJ10 telephone type
4-4
Fieldbus serial communication
ModBus RTU, type RS485, baudrate 1200...115000Kbit/s
CANOpen
Profibus DP
Ethernet Modbus TCP
Ethernet IP
EtherCAT
POWER (Solid-state relay)
AC 51 resistive or low inductance loads
AC 55b short wave infrared lamps (SWIR)
AC 56a transformers (Request application check)
PA - load control via adjustment of firing phase angle
ZC - Zero Crossing with constant cycle time (settable in range
1-200sec)
BF - Burst Firing with variable cycle time (GTT) optimized min.
HSC - Half Single Cycle corresponds to Burst Firing that
includes ON and OFF half-cycles.
Useful for reducing flicker with short-wave IR loads (applied only
to calibrate each time you change feedback mode.
V, V2 Voltage feedback: proportional to RMS voltage value on
load to compensate possible variations in line voltage.
I, I2 Current feedback: proportional to RMS current value on
load to compensate variations in line voltage and/or variations in
load impedance.
W Power feedback: proportional to real power value on load
to compensate variations in line voltage and/or variations in
load impedance. You have to calibrate each time you change
feedback mode.
480Vac
90...530Vac (models 480V)
1200Vp (models480V)
50/60Hz auto-determination
1000V/µsec
4KV
5KA/480V
Warning: Maximum permissible inductance loop impedance
1000uH
RC
10K...1Mbit/s
9,6K...12 Mbit/s
10/100Mbit/s
10/100Mbit/s
100Mbps
45