Technical Characteristics - gefran GFW-Xtra 40 Installation And Operation Manual

Modular power controller with overcurrent fault protection
Table of Contents

Advertisement

INA Analogic control inputs
Function
Voltage
Current
Potentiometric
IN1 Analog process inputs (option)
Function
Max. error
Thermal drift
Sampling time
Thermocouple Tc (ITS90)
Resistance thermometer RTD (ITS90)
Voltage
Current
IN2,...,IN5 auxiliary analog inputs (option)
Function
Accuracy
Sampling time
Thermocouple Tc (ITS90)
Voltage
Line Voltage measurement, Current /Voltage (optional) on load
RMS line voltage measurement function
Accuracy RMS line voltage measurement
RMS current measurement function
Accuracy RMS current measurement
Function voltage measurement RMS on load
Accuracy RMS voltage measurement on load
Thermal drift for measure tension and current in the load,
tension of line
Current and Voltage sampling time
INDIG1,...,INDIG3 Digital inputs
Function
Type
OUT1, ..., OUT3 heat control connected directly to solid-state units
Function
44
5 • TECHNICAL CHARACTERISTICS
INPUTS
Acquisition of % value for power control
Linear: 0,...,5Vdc, Ri>100Kohm
Linear: 0,...,10Vdc, Ri>100Kohm
Linear: 0/4...20mA, Ri =125ohm
1, ..., 10Kohm, max 10mA from 5Vdc power GFW
Acquisition of process variable
0,2% f.s. ± 1 scale point at @ 25°C
60 ms
J,K,R,S,T (IEC 584-1,CEI EN 60584-1, 60584-2)
Error cold junction comp. 0,1°/°C
Pt100 (DIN 43760)
Max line resistance 20ohm
Linear: 0,...,60mV, Ri>1Mohm
0,...,1V, Ri>1Mohm
a 32-segment custom linearization can be inserted
Linear: 0/4...20mA, Ri =50ohm
a 32-segment custom linearization can be inserted
Acquisition of variables (mV or Thermocouple)
1% f.s. ± 1 scale point @ 25°C
480 ms
J,K,R,S,T (IEC 584-1,CEI EN 60584-1, 60584-2)
Error cold junction comp 0,1°/°C
Linear: 0,...,60mV, Ri>1Mohm
Line voltage read 50-60Hz;
voltage in range :
90...530Vac for model with work voltage range 480Vac
1% f.s. with neutral connected, 2% f.s. without neutral
Load current read
2% f.s. @25°C in start mode ZC e BF; in mode PA 2% f.s. with
conduction angle >90°, 4% f.s. with conduction angle <90°
Load voltage read
1% f.s. with VLOAD option measurement
(Otherwise, the value is calculated from the values of line
voltage and power delivered; accuracy 2% F.S.)
<0,02%/°C
0,25 ms
Configurable (default: disabled)
Only for INDIG3: PWM input (100Hz/0,03Hz) to check the %
value of power which depends on the cycle; this function lets
you to set a power set point by means of a digital signal (ex.
from PLC or controller with PWM output).
5-30Vdc, 7mA isolation 1500V
OUTPUTS
Configurable (default: heat control)
State of control is displayed by LED (O1, ,O3)
OUT1 is connected to Master unit,
OUT2 and OUT3 are connected to Expansion units
< 100 ppm/°C of f.s.
80993B_MHW_GFW-Xtra_06-2018_ENG